IMAX Auto Referencing Absolute Magnetic Length Measuring System

Auto referencing absolute magnetic length measuring system

  • Resolution up to 1 mm
  • Measuring length up to 1000 m
  • CANopen interface (optional: SSI)
  • Actual position memory
  • Robust housing (IP67)

Description

Mechanical Data

Measuring principle

autonomous-referencing, absolute

Repeat accuracy

+/- 1 increment

System accuracy
in μm at 20 ° C

+/- (1250 + 20 x L)
L = measuring length in meters

Distance between sensor
and magnetic tape

1.8 mm

Basic pole pitch

4 mm

Sensor housing material

ABS plastic

Sensor housing dimensions

L x W x H = 50 x 12 x 25 mm

Required magnetic tape

AB20-80-20-1-R-D-17-BK100

Max. measuring length

1000 m

Cable connection

open cable end (standard)

Weight

100 g (without cable)

Environmental Specifications

Storage temperature

-25 … +85 °C

Operating temperature

-10 … +70 °C
(-25 … +85°C on request)

Protection class

IP67

Electrical Data

Power supply

10 … 30 VDC +/- 10%

Random and periodic
deviation

< 5%

Current consumption

max. 150 mA

Interfaces

CANopen

Resolution

1 mm

Max. movement speed

2 m/s

Sensor cable

cable length max. 30 m
(depending on BIT rate)
drag chain compliant