KMIX2 Magnetic Incremental Length Measuring System

Magnetic Incremental Length Measuring System

  • Round sensor with M10 fine thread
  • Integrated translator
  • Small and compact design
  • Easy to install
  • System resolution of 25 µm (at 4-edge triggering) resp. 0.1 mm (at simple edge triggering)

Description

Mechanical Data

Measuring principle

incremental

System accuracy in µm at 20 °C

+/- (25 + 20 x L) L = measuring length in meter

Distance tape / Sensor

max. 2 mm

Housing

stainless special steel

Necessary magnetic tape

MB20-50-10-1-R-XX.X

Environmental Specifications

Storage temperature

-25 … +85 °C

Operation temperature

-10 … +70 °C (-25 … +85 °C on request)

Protection class

IP67

Electrical Data

Resolution

0.1 mm at 1-edge triggering
0.025 mm at 4-edge triggering

Output current

max. 20 MA per channel

Index pulse (every 5 mm)

period time depends on operation speed

Supply / output level

5 VDC /  5 V-TTL line driver output

Tolerance / supply voltage

+/- 2,5%, ripple < 50 mV

Consumption

max. 200 mA

Output frequency

40 kHz (per channel)

Operation speed

max. 4 m/s (at optimal evaluation)

Wire length

max. 10 m

Supply / output level

10 – 30 VDC / 5 V-TTL line driver output

Tolerance / supply voltage

stabilized, ripple max. 5%

Consumption

max. 150 mA

Output frequency

40 kHz (per channel)

Operation speed

max. 4 m/s (at optimal evaluation)

Wire length

max. 50 m

Supply / output level

10 – 30 VDC / 10 – 30 VDC output

Tolerance / supply voltage

stabilized, ripple max. 5%

Consumption

max. 150 mA

Output frequency

40 kHz (per channel)

Operation speed

max. 4 m/s (at optimal evaluation)

Wire length

max. 30 m